EKOLOGICZNA WIELKOPOLSKA 2026 (Nabór wniosków pożyczkowych na przedsięwzięcia z zakresu ochrony środowiska i gospodarki wodnej)
WFOŚiGW Poznań · National call
Summary
Not an R&D or investment call a Polish company can use, by Scindu's rule.
Loans support companies, public bodies, cooperatives, universities, NGOs and other eligible entities implementing environmental and water management investments in Wielkopolskie.
- Who can apply
- Companies can lead: SME, large company, municipality, public body, university, NGO, other.
- Amount
- Budget not stated
- Deadline
- 30 Nov 2026in 37 days
- Status
- Openopened 20 Feb 2026
Machine-classified from the call text; check eligibility at the source.
Description
The description is on the provider's page.
Who can apply, in detail
- Applicant types
- SME, Large company, Municipality, Public body, University, NGO, Other
- Purpose
- Energy, environment, infrastructure
- R&D relevance
- 0 of 3
- Poland eligible
- Yes
- Country limit
- Projects in Wielkopolskie Voivodeship, Poland.
- Region
- wielkopolskie
- Consortium
- Single applicant
- Readiness level (TRL)
- —
- Topics
- Renewable energy and storage
- Wastewater management
- Circular economy
- Low-emission transport
- Green infrastructure
- Biodiversity
Machine-classified from the call text; check eligibility at the source. 24 Oct 2026
Conditions
Typed facts extracted from the source documents by Scindu's grant-data review. Each value keeps its own conditions. Unknown means unstated, not zero or unlimited.
- Applicant typeApplicants for projects located in Wielkopolskie
- Eligible applicants include local-government units and their associations; public-service entities; housing cooperatives; water companies; energy cooperatives; capital companies; legal persons of churches/religious associations; independent public health-care entities; public universities; public cultural institutions; other legal persons (including public bodies and public-benefit NGOs); housing communities; and State Forests.
Project must start no later than application year or the following year. Full categories are separately listed in the call page.
- Eligible geography2026 call
- Projects implemented within Wielkopolskie Voivodeship.
Applicants must be one of the listed legal entities.
- Eligible project scopeEkologiczna Wielkopolska 2026; Wielkopolska region
- Environmental investments in air quality/energy, renewables/storage, low-emission transport, geothermal, heating/electric networks, efficient lighting, wastewater/sludge, stormwater, green infrastructure, waste collection/recovery/recycling, contaminated-waste remediation, circular economy, environmental education, biodiversity/ecosystems, Park & Ride, and noise protection.
Eligible deliveries, construction works and services must be necessary to achieve ecological effect. Necessary project documentation also eligible.
- Other conditionPost-selection, pre-agreement stage
- Before signing the support agreement, the current schedule requires environmental-compliance certificates, an authorization/resolution including repayment security, and procurement-route declaration, among other conditions. RIO opinion applies to JST; technical permits and fire-safety/geotechnical evidence apply only when required by project scope.
The Fund’s award letter may identify additional documents; listed items are not a representation that the application has been approved.
- Other conditionPre-award application stage; applicant and project-specific attachments
- The current application attachment list requires an appropriate physical/ecological-effect form or equivalent description; public-aid forms only if the application’s four aid-screening answers are all affirmative; legal-form documents as applicable; and an energy audit where required by project scope. It also requires cost/scope evidence.
Exact attachment selection is conditional on the aid assessment, applicant legal form, and project scope; listing a requirement does not establish the applicant’s response or project facts.
- Other conditionConditional public-aid form for the final beneficiary, application/pre-award aid assessment
- The linked XFA form is a final-beneficiary declaration about public-aid status. It asks four questions on (1) whether the final recipient conducts economic activity under EU competition law, (2) whether the project relates to that activity, (3) actual/potential competition, and (4) actual/potential effect on trade between EU Member States. A “no” response requires a detailed justification of up to 600 characters or an attachment; the form concludes with the recipient’s public-aid/non-aid determination. The embedded dataset contains blank/default field values; no answers are inferred.
The final beneficiary completes the form; this review contains no applicant answers and does not determine whether state aid is present.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- FundtestsStateaidunderaccesscriterion2.10. Finalbeneficiarymayreceiveapplicablegeneral/SGEI/agriculture/fisherydeminimis,regional/horizontalenvironmentinvestmentaidorSGEIcompensationunderlistedacts. Ifapplicantisnotfinalbeneficiary,itmayreceiveindirectaidandassumeaid-providerdutiesaftercontract. Loan-grantaiddateiscontractsignature;remissionaiddateisBoardresolutionandregimeisbranchspecific. Noapplicantresponses/currentlegalclassificationorinferredthresholds.
- Other condition2026 call
- Applications from 20 February through 30 November 2026 or until the funds allocated to the intake are exhausted; the Fund may close earlier when funds are exhausted.
Current regulation§4 uses Generator preparation plus signed ADE/ePUAP filing; sending only within Generator is not submission. No paper filing requirement. Current availability/balance not inferred.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- Distinct§7(3)loan covers own contribution to nonreturnable domestic/foreign public cofinancing: up to100%eligible costs, wholly repayable; fixed2%annualunpaidprincipal or requestedEUreferencevariablefloor2%withcredit/securitymargin;principalgrace≤1yearfromcontractualcompletion,repayment≥3years,agreement≤15yearsfromsignature. Not ordinaryremissibleloan orliquiditybranch.
- Other conditionNoise-screen technical branch; additional conditions only for screens integrated with PV.
- Acoustic screens must follow the cited environmental/noise provisions and the annex’s expressly identified editions: PN-EN 1793:2017 with parts 1793-1, 1793-2 and 1793-3; PN-EN 1794:2020 with parts 1794-1 and 1794-2; and PN-EN 14388:2022. PV-integrated screens must meet all ordinary screen requirements, have at least 15-year PV-system durability and performance monitoring; no minimum yield is required for this screen-integrated PV branch.
Retain the standards and editions exactly as named in the January 2026 annex; no claim is made that editions are currently valid or that later standards supersede them. PV-specific conditions apply only to PV-equipped acoustic screens.
- Other conditionEnergy audit and all project categories needing administrative permits or grid conditions.
- Energy audit follows cited detailed audit rules and incorporates thermal-work scope. Any required final administrative authorization must be delivered by the assistance notice deadline and before loan activation. Fuel-combustion installation approvals and required grid connection conditions are likewise delivered as specified.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionBiomass and solid-fuel boilers.
- Biomass boilers meet Ecodesign implementing requirements and the cited solid-fuel-boiler energy-labelling requirements; solid-fuel boilers also satisfy applicable local-law requirements.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionPublic and other EV charging stations, including stations integrated with PV.
- Station includes charging point(s), charging software, corresponding parking bays and grid connection where applicable. Public stations give equal access; integrated PV charging kits do not need minimum energy yield. AC normal/high power connectors use Type 2; DC high-power uses Combo 2. Location-plan compatibility where applicable; connection terms, construction notification, President of UDT technical documentation opinion, EIPA data, and positive initial and in-service inspection records; inspection protocol submitted with payment request.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionAll building products, devices, installations and works; applicant implementation duties.
- Products/devices new; lawful placing on market; CE/declaration where applicable; devices have Polish-language manuals; written quality warranty for products/devices/installations. During works applicant protects environment and nature; before thermal modernization inspect for protected-species habitats, obtain required regional environmental derogation, protect nesting places, follow decision conditions; habitat destruction prohibited. Heat-source compliance evidence is by certificates, energy labels or manufacturer certificates.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionThree distinct technical branches: air/water or ground-source heat pumps for space heating; air-to-air heat pumps for space heating; heat pumps for domestic hot water.
- Air/water and ground-source heat pumps used for space heating: minimum energy-efficiency class A+ under the cited heat-pump/residential-label rules. Air-to-air heat pumps used for space heating: separately minimum class A+ under the cited air-conditioner energy-labelling rules. Heat pumps for domestic hot water: minimum class A under the cited water-heater energy-labelling rules.
The A+ air-to-air condition is a separate category with its own cited label regime; the A DHW condition applies only to domestic-hot-water production. Class labels are not converted to numeric performance or funding rates.
- Other conditionComplete household biological wastewater treatment plants with biological reactors.
- Require performance declaration under PN-EN 12566-3 or newer and notified-laboratory test reports supporting declaration. Geological documentation and licensed-geologist opinion must establish site suitability; profiles at each infiltration-device location.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionShallow geothermal projects and ground heat exchangers.
- Low-temperature geothermal means heat insufficient for direct heating/cooling without heat-pump technology; the source describes groundwater use to 100m depth and 25–30% antifreeze mixture or brine. Preserve the source’s distinct procedural branches: ≤30m excavations/boreholes outside mining areas are described as exempt from Pgig notice; 30–100m requires geological-works project notification and, if required, other geological documentation; ground heat exchangers with ground-source heat pumps to ≤30m are described as outside Pgig; borehole exchangers >30m outside mining areas are geological works. PRG is not approved by administrative decision; county starosta can object within 30 days. Required final administrative permissions are delivered by notice deadline before disbursement.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionSupply-and-exhaust mechanical ventilation with heat recovery.
- Automatic control must allow capacity adjustment to current needs; Ecodesign and residential energy-labelling requirements apply.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionPark-and-ride parking at public-transport nodes.
- Comply with building technical conditions and local spatial plan (or municipality study if no plan); construction notification or permit. Parking should have isolation greenery and stormwater storage under parking. Permeable paving is capped at the stated runoff coefficient; additional listed equipment is recommended.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionPhotovoltaic modules and installations.
- Modules must have an eligible PN-EN 61215 or equivalent certificate; inverter conformity to PN-EN 50549 and CE marking; foreign-language certificate requires translation. Rooftop works consider roof structural testing; protections against surge/lightning are required where the installation design requires them; project designed by a licensed electrical/energy-installation designer. For installed electrical capacity above 6.5 kW: fire-protection expert approval of design and completion notification to the competent State Fire Service.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionProjects unsealing impermeable surfaces and rainwater management.
- Ground testing precedes depaving; geotechnical opinion by geological licence category XIII, supported by boreholes. Site criteria are cumulative: permeable ground of listed types at ≥1m below ground, groundwater meeting the exact source depth condition, runoff to storm or combined sewer on application date, and no change in land use. Listed runoff coefficients are for calculations; separate rain design statements are recommendations. The groundwater clause is retained verbatim (“na głębokości poniżej 1 m”) and is not reinterpreted as a derived threshold. Source runoff coefficients by surface: asphalt Ψ=0.90; sealed clinker or stone Ψ=0.80; concrete/concrete slabs Ψ=0.80; concrete-slab footpath Ψ=0.60; paved surface Ψ=0.50; openwork slabs Ψ=0.40; crushed stone Ψ=0.35; gravel Ψ=0.25; biologically active grass eco-grid Ψ=0.25; gravel-filled eco-grid Ψ=0.25.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionProjects including sewer connections.
- A sewer connection means the connection under the cited water-supply/sewerage act, together with elements necessary to physically connect the internal building installation to the sewer network.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionSolar collectors for domestic hot water and/or supplementary heating.
- System serves DHW or DHW plus other heat consumers including central heating. Collectors require certification to PN-EN 12975-1 or PN-EN 12975:2022 together with PN-EN ISO 9806 test report, or a Solar Keymark awarded by an accredited certification body.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionModernized street lighting.
- Modernized street lighting must meet PN-EN 13201:2016.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionThermal insulation, windows/doors, internal heating and domestic hot-water installations.
- Insulation work follows the cited building technical conditions; an insulation system covered by one reference document is installable only as the complete set; insulation covers all elements in the energy audit. Use warm-installation methods for windows/doors where technical conditions permit, including installation in the insulation layer and inside/outside vapour-control sealing. Economically unjustified projects are not fundable. Pipe and fitting thermal insulation follows the cited building technical conditions.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionWind, hydro and non-prosumer photovoltaic power-plant construction.
- Wind: final building permit required. Hydro: final water-law consent and building permit. Non-prosumer PV plant: final building permit. Required decisions are submitted by the notice deadline and before loan activation.
Apply only to matching project types and only as expressly specified; preserve source-stated conditional wording and recommendations.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- For substituteexecution/Art26a pursuecostrecoveryfromobligor;remitrecoveredfundstofundfirstuptoFundliabilitywithin14daysfromreceipt. Recoveryreduceseligiblecosts,loanandplannedremission;fullrecoveryterminatesagreement. Substituteexecutionremissionalso requiresfinalwhole/partialterminationofadministrativemonetaryenforcementforreasonsotherthanspecifiedstatutoryexceptions.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- Distinct§7(5)JSTbranch covers substituteexecution/Art26awasteremoval andArt24acompliantwastestorage: up to100%eligiblecosts,maxPLN20000000;remission≤40%principal,maxPLN2000000perproject;fixed0.5%annualunpaidprincipal;grace≤1yearfromcontractualcompletion;agreement≤15yearsfromsignature. Ifinsufficientfunds prioritizeArt26a,then substituteexecutionenvironmentalthreat evidencedbyadministrativedecision,thenothers. Substituteexecutionapplicationincludeslawenforcementnotificationofenvironmentaloffencesorstatementnocrime/offenceindications. Actualpriority/awardnotinferred.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- Distinct§7(4)liquidityloan up to100%eligiblecosts,whollyrepayable. Variablerateis billrediscountfromlastbusinessdayofprecedingyear; source gives no2.5%floor/4%cap for thisbranch. Maximumrepayment36monthsfromfinancialcompletion,definedfootnote5aslastprojectpayment. Under§5(3)eligiblecostsarepaidfromapplicationdate.
- Other condition2026 loan financing
- Costs incurred before application are ineligible for Fund financing.
Payment-liquidity loans are governed by separate provision.
- Other conditionOptional loan branch
- Applicant may request a fully repayable loan with no remission.
Terms differ for counterpart-financed contribution loans; see separate provision.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- Remissionapplicationrequiresontimecompletion,approvedfinalsettlement,repayment/interesttimeliness(totaldelay≤30daysforrepayment≤6years,≤40daysiflonger),ecologicaleffectandreinvestmentinotherenvironmental/waterprojectswithdocumentedplanandlaterexecution. Achievedeffect≥20%ofplannedvalueallowsproportionalplannedremission;below20%losesremission. Loansshorterthandurability(excludingremittedinstalments),projectswithnonreturnablepublicfinancingandnonzero/nonlowemissionvehicleloansnotremissible. Excessdelayreducesremissionby50basispointsperdaybeyond30/40;lateinterestexcludedifitsaggregate≤10%interestdue. Wholeprojectscopealwaysrequiredirrespectiveawardlevel.
- Other conditionAgreement, disbursement and post-award settlement stage
- The current route links a disbursement/repayment schedule attached to an agreement, a settlement workbook, and 2026 partial/final settlement instructions. They apply after agreement and during drawdown/settlement, not as pre-award eligibility proofs.
A10PP is specifically for liquidity-preservation loans; no liquidity loan or drawdown is inferred for this record.
- Other conditionCall eligibility
- Project must start no later than the year the application is filed or the following year.
Projects must be implemented in Wielkopolskie and must satisfy ecological-effect criteria.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- Awardwithinallocation. Fundnotifiesaward/form/contractdocumentswithin15workingdaysfromBoardorSupervisoryBoardawardresolution. Requestedprecontractupdatescanchangescope/name/account/VAT;increasealso requirescontractoragreementsandfunds;competentBoardupdatesaward. Noncompliancefoundindocuments/controlrevokesawardwithoutclaim. Appealonlycriteria2.4–2.10,not2.1–2.3,toADE/ePUAPwithin7calendardaysfromrejectionreceipt;Fundresponse30calendardaysfromappealreceipt,finaldecision;late/unauthorized/unavailable/ungroundedappealsfail. ContractcomputerprepareddocumentsmustreachADE/ePUAPbystateddeadline;missing/latecouldloseaward. Written/electronic/documentarycontract;annexforchangesunlessotherwiseagreed;nolegalformchangebeforesigning;rights/formchangesdurabilitycheckedandreported;disbursementpercontract/settlementinstructions.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- All10accesscriteria apply:correct call/form,eligible entity,creditworthiness,notcompletedproject,attachments,completeaccuratesigneddocuments,allowedform/amount,costcatalogue,ecologicaleffect,Stateaid. Target50workingdays may change. Criteria2.1–2.2failure rejects without correction; negativeequity fails creditworthiness2.3; Fundmayrequestclarification, failureaftertwo corrections rejects. Criteria2.4–2.10allowtwo corrections exceptupdateapplication; audit/costestimate have separate requestedcorrection branch. Response to ordinary remarks viaePUAP/ADE within7workingdays from emaileddispatch; latefirstresponsecountsassecond; audit/costestimateresponse uses notice-setdeadline. Unrequestedcorrection notassessed. Uncured/late/missing/aidproof/adverseextrachanges reject; finalBoardlistfollows.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- Applicantmustpromptlyreportaddressandmaterialprojectchanges throughdurability, maintainworkingdeclaredemail; neglectedoldaddressserviceiseffective. Fundemail/ePUAP/ADEdeemeddeliveredondispatch; toFundreceiptgoverns. Participationacceptsincorporateddocuments. Funddeadlinesareinstructiveunlessspecificsanction,breachcreatesnoclaim. Justifiedrequestfromdeclaredemail/ePUAP/ADE canextenddocumentdeadlineifBoardaccepts. Fundmayamendrulesbeforeallcontractswithoutworseningparticipationconditions;documentaryemaillegalactspermitted;disputescourtatFundseat.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- Fund can inspect implementation and use from application through durability expiry, at applicant premises, project site or remotely. Applicant/beneficiary must provide project records and access to devices,objects,land,premises; obstruction, incompleteaccess or refusing remote documents counts as refusal of inspection.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- §13(7)exceptions:JST/unions;commercialcompanies≥51%direct/indirectStateTreasury/JST/unionssharecapital;publicuniversities;State/municipalculturalinstitutions;SPZOZ;watercompanies/unionswithJST/unions≥51%generalmeetingvotes. Allstillrequireblanknote/declarationandBoardmayrequestadditionalsecurity. Fundsetsform/term,mayrefusesigningforabsent/unacceptedsecurity. Multiplecallapplications/agreementsaggregate;eachagreementcausingtotal>PLN150000useshighersecuritybranch. Establishingsecurityconditionofdisbursement.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- For loans≤PLN150000, require blank promissory note/declaration plus Art777§1(5)enforcement submission of minimum principal+30%, subject§13(7)entity exception. Board may demand additional§13(3)security in justified cases. Multi-agreement aggregation under§13(10)can trigger the higher branch.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- For loans>PLN150000, blank note/declaration plus accepted additional security: bank guarantee,note/civil surety,registered pledge,cash deposit,mortgage,assignment or account/deposit blocking; other lawful types possible. At least two securities under§13(3), with minimum non-note value principal+30%, subject§13(7). Fund may add enforcement instruments Art777§1(4),(5),(6). Establishing security is a condition of disbursement.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- PreparecurrentGeneratorformwithcontrolID;qualified/trustedsignaturebyproperrepresentativesandsignedattachments,separatesignatureswithoriginalfilesifdetached,thenfiletoADE/ePUAP;Generator-onlynotfiling. Wrongforms/noID/trialprint/orphancorrection/update/attachments/wrongchannel/lateapplicationsnotprocessed;Fundnotice≤30workingdaysfromfiling. Duringintakemaywithdrawfromdeclaredemail/ADE/ePUAP. RequestedcorrectionsinGeneratorandsamesignedfilingroute;updatesaredistinctandreassessedagainstaccesscriteria.
- Other conditionExact current incorporated source with dedicated-programme precedence; no individual award, borrower classification, acceptance, available funds or performance outcome inferred.
- Whole-project procurement must preserve fair competition/equal treatment and economical purposeful expenditure. PZP-obligated entities use PZP for the whole project; below relevant classic/sector thresholds use public-financeArt44 or internal rules. Non-PZP entities use CivilCode tender/negotiation rules for netorders≥PLN10000, or the web-offer CivilCodeArt66§1 route for qualifying supplyorders≥PLN10000, as specified in each agreement and applicable Fund guidelines. This does not assert a completed procurement outcome or supply missing guidelines text.
- Technical requirement, maximumNormal-power electric vehicle charging point
- 22 kW charging point power
Source defines normal power as 3.7–22 kW; high power is strictly greater than 22 kW.
- Technical requirement, maximumPark-and-ride parking to transit stops or nodes
- 500 m maximum route distance
Measured with hardened and illuminated pedestrian routes.
- Technical requirement, maximumParking spaces made of permeable materials
- 0.4 dimensionless runoff coefficient Ψ
Applies to this P&R paving condition; not the rainwater-depaving table values for other surfaces.
- Technical requirement, maximumHeat-recovery mechanical ventilation system
- 0.5 Wh/m³ electricity input coefficient
Source maximum coefficient; automated capacity control is a separate categorical requirement.
- Technical requirement, minimumPhotovoltaic system integrated into acoustic screen
- 15 years minimum PV system durability
Applies to PV systems on acoustic screens; the annex also says no minimum yield is required for this application.
- Technical requirement, minimumHousehold biological wastewater treatment site suitability
- 2.2 m vertical separation from existing ground level to groundwater
Combined with minimum permeability class C and site-specific documented wastewater discharge capacity.
- Technical requirement, minimumEach household biological wastewater treatment plant infiltration location
- 4 m geologic profile depth
Geological profile must include relevant soil layers, permeability and groundwater information.
- Technical requirement, minimumGeotechnical opinion for impermeable-surface depaving
- 1.5 m below ground level
Opinion based on boreholes at least this deep; density and site criteria are separate conditions.
- Technical requirement, minimumPermeable soil occurrence under planned depaving surface
- 1 m below ground level
Cumulative site suitability condition; source lists gravel, mixed gravel, sand and silty sand.
- Technical requirement, minimumNormal-power electric vehicle charging point
- 3.7 kW charging point power
Source defines normal power as 3.7–22 kW; strictly above 22 kW is the distinct high-power class.
- Technical requirement, minimumPhotovoltaic installation electricity yield
- 900 kWh per kWp per year
Minimum yield; integrated PV charging stations and acoustic screens have explicit source exceptions from minimum yield.
- Technical requirement, minimumHeat-recovery ventilation unit
- 85 percent temperature efficiency
Reached in at least one measurement range per the source-named measurement standard.
Amounts and costs
- Grace period, maximumWhollyrepayableown-contributionloantononreturnabledomestic/foreignpublicfunding§7(3)
- 12 months from contractual project completion
Principalrepaymentgrace,notagreementmaturity.
- Grace period, maximumPrincipal repayment grace
- 12 months from contractual project completion date
Maximum, not guaranteed duration. Ordinary§7(2)principalgracefromcontractualprojectcompletion;otherbranches separatelyrepresented.
- Loan interest, fixed rateWhollyrepayableown-contributionloantononreturnabledomestic/foreignpublicfunding§7(3)
- 2 percent per annum on unpaid principal
CounterpartalternativeEUreferencerateonlyonrequest;JSTwastefixedspecificbranch.
- Loan interest, fixed rateJSTwasteremoval/storage§7(5),specificsubjectmatterandpriority/evidence/recoveryconditions
- 0.5 percent per annum on unpaid principal
CounterpartalternativeEUreferencerateonlyonrequest;JSTwastefixedspecificbranch.
- Loan interest, minimumRequestedEUreference-ratealternativefor§7(3)counterpartloan
- 2 percent per annum on unpaid principal
Baserefpluscredit/securitymargin;notordinary2.5%floor.
- Loan interest, minimumStandard variable loan rate
- 2.5 percent per annum
Calculated on unpaid principal using bill rediscount rate set from the last business day of preceding year; capped at 4% annually. Optional EU reference-rate branch has a 2.5% floor, with margin determined from creditworthiness/security; loans over PLN10m may have separately approved terms. MorefavorabletermsrequireBoardproposal/SupervisoryBoardacceptanceforamount>PLN10000000;footnote4revertstostandardinterestifamountfallsbelowPLN10000000.
- Loan partial remission, maximum amountJSTwasteremoval/storage§7(5)
- PLN 2,000,000
Also40%principalcap;notordinary15/25/35branch.
- Loan partial remission, maximum amountLoan partial remission
- PLN 2,000,000
This monetary ceiling applies in addition to the percentage cap for the selected eligible remission branch.
- Loan partial remission, maximum shareJSTwasteremoval/storage§7(5)
- 40 percent of awarded loan principal
AlsoPLN2000000cap;recoveryandperformancegatesapply.
- Loan partial remission, maximum shareGeneral remission branch
- 15 percent of loan principal granted
Subject to exceptions, eligibility, programme conditions and PLN2,000,000 maximum per project; borrower may request fully non-remissible loan.
- Loan partial remission, maximum shareJT and majority-public-owned commercial company branch with minimum 12-year repayment term
- 35 percent of loan principal granted
Latest amendment effective 25 September 2026; PLN2,000,000 per-project ceiling applies. Excludes remission installments from repayment duration calculation.
- Loan partial remission, maximum shareJT/association and majority-public-owned commercial company branch with minimum 7-year repayment term
- 25 percent of loan principal granted
Must meet listed applicant category; statutory programme conditions and PLN2,000,000 per-project ceiling apply.
- Loan principal, maximumJSTwasteremoval/storage§7(5)
- PLN 20,000,000
Also100%eligiblecostceiling;conditionalprioritiesandevidence.
- Loan principal, maximum shareWhollyrepayableown-contributionloantononreturnabledomestic/foreignpublicfunding§7(3)
- 100 percent of eligible project costs
SubjectactualFundaward;separatefromordinaryloan.
- Loan principal, maximum shareWhollyrepayableliquiditypreservationloan§7(4)
- 100 percent of eligible project costs
Paidcostsfromapplication;variablerediscountnoborrowedordinaryfloor.
- Loan principal, maximum shareOrdinary loan under§7(2), separate from counterpart, liquidity and JST waste branches.
- 100 percent of eligible project costs
Project-finance special-purpose companies must contribute at least 15% of eligible costs. Award subject to resource availability and detailed review.
- Loan term, maximumWhollyrepayableown-contributionloantononreturnabledomestic/foreignpublicfunding§7(3)
- 180 months from agreement signature
Maximumagreementterm.
- Loan term, maximumLiquiditypreservationloan§7(4)
- 36 months from financial project completion
Footnote5financialcompletion=lastprojectpayment;notfromsignature.
- Loan term, maximumOrdinary loan§7(2) maximum agreement duration from signature.
- 180 months from agreement date
Minimum repayment length is 3 years; specific security and schedule are determined by the Fund; certain remitted installments excluded from duration in 7-/12-year remission tests.
- Loan term, minimumWhollyrepayablecounterpartloan§7(3)(6)
- 36 months of repayment
Repaymentminimum,not36monthmaximumliquiditybranch.
Source documents
- Attachments required before agreement
- Agreement document schedule workbook
- Agreement settlement spreadsheet
- Current application attachment list (June 2026)
- Linked beneficiary information XFA PDF; rendered body unavailable
- Ekologiczna Wielkopolska 2026 call detail page
- Board amendment 61/1524/2026 of 25 September 2026 to 2026 recruitment rules
- Annex 2 to agreement: payment and repayment schedule for liquidity loan
- 2026 programme regulation and loan conditions
- 2026 partial/final loan and grant settlement instructions
- Technical requirements for 2026 loans
Call facts
- Opens
- 20 Feb 2026
- Provider
- WFOŚiGW Poznań
- Source
- wfosgw.poznan.pl
- Checked
- 24 Oct 2026
- Review status
- Partial review
- Independent QA
- No published hold
- Reviewed
- 24 Oct 2026
This is a summary of the source page, not the official text. Eligibility, conditions and the submission system are at the source.